Old Style Removal Old Style Pitless Adapter

It uses 3/4" threaded pipe. Yet you will notice price decreases in our nipples and rough brass threaded fittings. Bottom line: There was no way to clean this out, so a new water line went on the shopping list for the hardware store. This feature is what allows us to pull the well piping and submersible pump or foot valve completely out of the well without having to dig up and expose and disassemble the pitless adapter from outside the well. Odd Pitless adapter help needed. The idea was that every well was identified and a sanitarian could walk up to it, get the ID number and determine exactly what this well was as it was recorded in the well record. This is just a follow on note to capture a lesson learned... You never have to worry about the Retro-Line pipe heating cable overheating causing a risk of melting and fire because of the self-regulating pipe heating cable technology. If you don't want to have to pull your well pump up out of the casing again, just to change the wiring three years after you did the job, maybe take care of it while you have it out of the ground the first time. When ready to make the electrical connections, make sure to put the heat shrink plastic onto each wire before making the crimp connections. Q- Is there a maximum length of Retro-Line heating cable systems? The most common application for slide pitless adapters is for submersible pumps.

Old Style Removal Old Style Pitless Adapter Video

Feed the pump back into the casing slowly, using the safety rope. Warning: I did this with power applied. That can lead to the pump constantly switching on/off... which eventually burns out the pump, or the pump switch. A – It is not uncommon for a Retro-Line system to insert and push into a pipe for distances as long as 150 ft. (45. It is not uncommon to push systems up to 150 ft. Post your water well and pump questions. (46m). In a drilled well application, the heater can run the length of the pipe, but cannot enter the pitless adapter or it may sustain damage. Step 27: Victory Dance!

Pitless Adapter Removal Tool

You basically have three "lines" running down into the well. Some casings can be as narrow as 4". The term "pitless" comes from the fact that pitless adapters eliminate the need for a "Well Pit". Did you notice the piece of safety rope tied directly to the pump? A gallon is 8 pints, so a single gallon will be enough to do the job AND sanitize the well cap before I put it back on. Old style removal old style pitless adapter work. It worked beautifully for me. Well... the well pump is only 4" wide. It doesn't take much for it to split. I wrote this ible in May of 2015. Once the pitless adapter has been removed from the pipe, the person holding the lock cable can then grab the pitless adapter.

Old Style Removal Old Style Pitless Adapter Line

The pressure switch on the tank is set up so that it knows what point to turn ON the pump (pulling water up from the well to replace what you've used), and what point to turn OFF the pump (to keep your system from exploding). DO NOT CUT HEATING CABLE or POWER LEAD. It is however recommended to expose these fittings and check the inside to make sure there are no rough edges or burrs which may potentially injure the heating cable jacket. If the kit is for a PVC casing, it will include a curved plate that goes between the U bolt and the casing so tightening will not crush the more fragile plastic material. In Pipe Heating Cable | Pipe Heater Wire | Heat-Line. Traditional or standard water line heat tape, water line heat wrap, heat trace tape, and pipe heat wire systems do not offer this level of installation capability. As you can see from the picture, these two types of pitless adapters look nothing a like.

Old Style Removal Old Style Pitless Adapter Plate

I genuinely recommend that you do a little searching around on the web for a replacement pump before jumping in your car and assuming that Home Depot or Lowes will have the one you need, in stock. Be sure to check with your local jurisdiction to ensure the adapter you are using complies with your local codes. But some things are still being used everyday and these include, but are not limited to, submersible pumps, tanks, well screens and many other items.

Old Style Removal Old Style Pitless Adapter Work

Step 20: Selecting a Replacement Pump at the Hardware Store. To further increase the energy efficiency of your Retro-Line water pipe freeze protection system, it is recommended to add thermal insulation and a thermostat. Should you have any abrupt elbow fittings, they must be replaced with pipe to create sweeping bends to allow the heating cable to pass. Standard pitless connectors use a 1" threaded pipe. Old style removal old style pitless adapter line. So I have written about cable tool and am always glad to talk about it. While you're at the hardware store make sure to pick up a set of crimp connectors for the electrical connections. Hooray for improvements in technology! Hi guys, I was at work the other day (I drill wells and install pumps and pressure tanks) and thought to myself, this might be something useful to take to the gj boards. For the pressure tank to work correctly, the ambient pressure (while completely drained) has to be -2lbs from the pressure at which you want the well pump switch to kick on. Before we head to the store to buy the replacement pump, we needed to make sure that the shopping list included EVERYTHING. Brass is a soft metal.

Old Style Removal Old Style Pitless Adapter For Concrete

Throw the filter away, place a new one inside, and screw the canister back in place. Always contact Heat-Line for guidance prior to proceeding. It appeared to me clear that the brass pipe was lower that the silicon brass on the corrosion chart and was therefore going to give itself up to corrosion to protect the silicon brass. So the pump installer ends up with, in effect, a scrap pile of short sections of pipe. While most Retro-Line systems are manufactured in standard lengths, special lengths of any measurement can also be requested within the maximum lengths allowed.

IF YOU HAVE A SEPTIC TANK (I don't) YOU'LL WANT TO CAPTURE ANYTHING OUT OF THE SINKS WITH A BUCKET, SO THAT YOU DON'T KILL OFF THE BACTERIA IN THE SEPTIC SYSTEM. When draining the water from a dwelling that is allowed to freeze, how does the water supply from the submersible pump, supplied with foot valve, drain so the at or above grade pipes don't freeze and break? Q – If the power fails, do I have to reset the unit? Is there a reason this is happening, no one else I know has this problem, is there something I can do permanently to fix the problem.

Step 22: Securing the Electrical Connections. I hooked up an air compressor and filled it until it reached that point. NOTE, the flex pipe will get slippery when you reach water level. The slide pitless is on the left and the spool type pitless is on the right.

You'll feel it bite. In actuality, we're not! It is now October of 2017. Lake/River Applications. A – All Heat-Line brand systems including Retro-Line employ Heat-Line's advanced self-regulating heating cable technology which operates to deliver energy and heat output to areas of the pipe that are cold and reduces energy and heat output to areas which are warm. Two reasons for this: 1) The wire I inherited was some kind of specialized, 12 gauge, submersible pump wire. It's a 220V, two-wire motor.

I've always used galvanized steel pipe for this "hanger" pipe, but several of my friends have been successful using schedule 80 PVC pipe. Since I knew that the well pump had been sitting in muck for who knows how long, it seemed like a good idea to shorten the length of the water tube. Then give the well cap a few "uppercut" swings with a medium-sized hammer. The Retro-Line self-regulating heating cable system is supplied in a predetermined length with all necessary components for a complete job-ready system. Once re-energized the Retro-Line system has the ability to increase its output to immediately begin to defrost any section of the pipe that has or was close to freezing during the power outage. Measuring/Ordering Recommendations for Retro-Line.

Once you get them all off, set them in a safe place for later. If wrong information about pipe and size is provided at the time of order then you will not be able to hook up the Retro-Line system to your pipe.