Water Technologies Water Softener Manual

Information in this manual is different than what is needed for installation and servicing of a particular water treatment system. If an extended power outage occurs, the time of day will flash on and off which indicates the time of day should be reset. Next and regen were pressed to reset the valve. Water flows through the control valve for normal operation of a water softener or filter. 1 on page 2) by opening the outlet bypass handle. If value is set to off regeneration initiation is based solely on gallons used. Teflon® tape is not used on the nut connections or caps because "O" Ring seals are used. ERROR If the display toggles between "Error" and an error code (i. a number), call a service technician and report the error code. A single-tank softener should be set to regenerate at night. Valve does not regenerate automatically but does when regen button is depressed 9. NOTE: Hardness display shows "-nA-" if used as a filter. 4 5 Operating Displays for the Softener: 1.

Water Tec Water Softener Manual

This manual is not intended to be used as a manual for a complete water softener or filter. Press and hold the regen button for 3 seconds until a regeneration begins. Where the drain line is elevated but empties into a drain below the level of the control valve, form a 7" loop at the discharge end of the line so that the bottom of the loop is level with the drain connection on the control valve. These units will deliver conditioned water for many years to come, when installed and operated properly. Without proper salt levels, the water softener may not operate properly. Model Brine Refill Backwash Brine & Rinse Rapid Rinse Total GACS835 Min. The control valve may be stepped through the various regeneration cycles by pressing the regen button. 5 amperes · the plug-in transformer is for dry locations only WELL WATER INSTALLATION MUNICIPAL INSTALLATION Air Gap To Drain Air Gap To Drain Waste connections or drain outlets shall be designed and constructed to provide for connection to the sanitary waste system through an air gap of 2 pipe diameters or 25 mm (1 in), whichever is larger. During the regeneration cycle this position provides regeneration water to the unit, while also providing untreated water to the distribution system (Fig. Herb Kirchhoff has more than three decades of hands-on experience as an avid garden hobbyist and home handyman. If there is a demand for water when the system is regenerating, untreated water will be delivered. If salt gets too low, the water system won't work properly.

If you're experiencing an issue with your system, here's a water softener troubleshooting guide to help you identify the problem and either fix it yourself or call a pro. Water Specialist WS1 and WS1. Normal Operation Position: The inlet and outlet handles point in the direction of flow indicated by the engraved arrows on the control valve. During these FILL and SOFTENING positions, you will have softened water available for use. Solder joints should be cool and solvent cements should be set before installing the nut, split ring and "O" Ring. 8 Start-up Instructions for Water Softeners: 8.

Water Soft Water Softener Manual

The words regen today will flash on the display to indicate that the system will regenerate at the preset delayed regeneration time. Press regen button again. If the system has called for a regeneration that will occur at the preset time of regeneration, the words regen today will appear on the display. Check to be sure your water softener is plugged in and that the outlet is hot.

Our detailed manuals and installation videos make most installations a breeze. Again, check drain that it can receive the flow of water. This takes about another 10 minutes. Power Loss: If the power goes out for less than two hours, the system will automatically reset itself. Adjust minutes with and buttons 5. If the dry salt storage feature is not being utilized, block salt may be used. This noise is only the brine tank filling and at no time during this process will you be without treated water.

Water Technologies Water Softener Manual Page

Note: The grains per gallon can be increased if soluble iron needs to be reduced. Press regen again to put valve in BACKWASH. Replace drive cap assy. Water quality may vary. Once the cycle operation has been verified, Place bypass valve in the normal operating mode (Fig. Press next to go to step 5. 1 Locking clip, elbow 1 2 Insert, 5/8" tube OP 3 Nut, 3/4" drain elbow OP 4 Drain elbow assembly, 3/4" NPT 1 5 O-ring 019 1 6 DLFC retainer assembly 1 0. Check the Bypass Switch. Adjust hardness using t and s buttons 3.

Time of day flashes on and off A. bypass valve not in normal operating mode A. see bypass diagrams on page 2 B. meter disconnected C. obstructed meter turbine D. defective meter E. programming error F. Power has been out more than two hours. The distance between the drain and the water conditioner should be as short as possible. After many years of hard water running through the tank, the resin can wear out. 2 1 Nut, 1" quick connect 2 2 Split Ring 2 3 O-ring 215 2 4 Fitting 2 1" BRASS SWEAT 3/4" BRASS SWEAT Item No. 2 DLFC for 3/4" elbow 5.

Water Softener Operation Manual

5" GACS1035 32, 000 @ 15. D iagnostic Position: The inlet handle points toward the control valve and the outlet handle points to the center of bypass valve. Since retiring from the news business in 2008, Kirchhoff takes care of a 12-acre rural Michigan lakefront property and applies his experience to his vegetable and flower gardens and home repair and renovation projects. 1 Spacer stack assembly 1 2 Drive cap assembly 1 3 O-ring 228 1 4a Piston assembly downflow 1 4b Piston assembly upflow 1 5* Regenerant piston 1 6 O-ring 337 1 12 Replacement Parts: INJECTOR ASSEMBLIES Item No. If it comes on during the day when water usage is higher, you may get hard water because the unit can't keep up with you. If the motor is not running fast enough or not running at all, the unit cannot work properly.

Generally speaking, the salt level should be 3 or 4 inches above the water level. If your valve doesn't look like the diagram below, contact your service technician for instructions on how to shut off water. STEP 3 Current Time (minutes): Set the minutes of the day using the s or t buttons. Do not elevate overflow line higher than 3" below bottom of overflow fitting. DRAIN LINE: First, be sure that the drain can handle the backwash rate of the system. BYPASS VALVE OPERATION To shut-off water to the system, please position arrow handles as shown in the bypass operation diagram below.

Do not use a pipe wrench to tighten nuts or caps. The 1" full flow bypass valve incorporates 4 positions including a diagnostic position that allows a service technician to have pressure to test a system while providing untreated bypass water to the building. Bypass Valve: The bypass valve is typically used to isolate the control valve from the plumbing system's water pressure in order to perform control valve repairs or maintenance. ATI Pure Platinum WholeHouse Water Conditioner -Valve Manual.