State Water Heaters Icomm Connectivity Platform | 2018-10-16 | Plumbing & Mechanical

Precise temperature control adjustable from 90 to 180 degrees. Flammable vapors and liquids in the. Meets NSF requirements when equipped with optional leg kit. ICOMM™ Elite Remote Monitoring Brochure (SCBBR00109). High Performance For High Demand: - Precise, powered-burner performance. Ultra Force® SUF/SUFL Service Handbook (100234735). Hazardous Material: False.

Re-Engineered To Be Even Better. The control system will display the "AC reversed". Rugged dependability is what makes the State Titan® series so popular. A Blower Prover Switch is a switch/sensor that a water heater's blower assembly relies on to sense air flow.

• 24 Volt Gas Valve on/off switch in the "off" position - see Figure 57. The CSB saves money and is durable, flexible, and also meets all code requirements. Click Here for Privacy Policy. • intake air and/or vent piping is restricted or improperly installed -.

Make sure the debris screen has been removed from the Intake vent If the unit will be Direct Vented (outside air). 45kPa) for propane and a minimum of 4. • The control system has detected low current (AC amps) from the. Color Finish: White. SBL Series – Fan Assisted Combustion / Ultra-Low NOx Gas. Product features a new high tech electronic control and commercial grade heavy-duty elements, all designed with energy-efficiency in mind. • Excessive equivalent pipe length, exceeded the maximum number. Intermittent electronic ignition eliminates pilot. Condensation and cold airman also block the air flow of the exhaust. 100 Gal 199900 BTU State Modulating Ultra Force Natural Gas Commercial Water Heater.

The (CCB) is set up to shut the unit down w henever there i s a failure of any of the switches and declare a fault for each individual switch. This number may change as software revisions are made. Ultra-Force SUF-120-250 Series 300/301 Parts List (100312928). Top mounted burner position prevents condensation from affecting burner operation. Marketing Resources. • The control system has detected the blocked Exhaust Switch. Fast installation due to factory-installed terminal block. Built-in diagnostics and can run history information. Light-Duty Patriot™ Perfect for small-demand Light-Duty Patriot™ delivers flexibility, with placement for almost any situation. Any installation or repair completed using the information provided in this production should meet the requirements of the applicable national, state, provincial and local codes in your area as well as the manufacturer's certified installation instructions that accompany the product. ULTRAFORCE COMMERCIAL GAS WATER HEATER SUF 120 thru 400 SERVICE HANDBOOK CHANGING THE DISPLAY UNITS The desktop menu has the option of selecting between degrees Fahrenheit and degrees Celsius for temperature displays.

WHEN THE UNIT IS TO BE SET UP AS A DIRECT VENT, THE BALANCE PLATE AND MESH SCREEN MUST BE REMOVED BEFORE GLUING PIPE TO THE CONNECTOR. Also in this menu, you may adjust how the back-light operates and the contrast of the LCD screen. The control performed selected system diagnostic checks immediately upon power up. You can always depend on the quality of the Premium Heavy-Duty Statesman™. Once connected, users can interact with one or multiple heaters on the app, adjusting temperature and differential, viewing status and fault history, and setting custom alerts.. State Water Heaters. Ultra Force™ - Most Efficient: SUF Series. Please contact your local Coburn's location to find out if the item can be ordered from the manufacturer and the estimated time it would take to be shipped. Hot Surface igniter. Warranty Information.

Call the technical support phone number listed on the back cover for further technical assistance or to locate a qualified service agent. Intelligent Demand Response (IDR) feature senses large water draws and automatically adjusts the differential setpoint. Part #SSUF100199NEAE | Item #3509139 | Manufacturer Part #100234907. • Water heater is not properly grounded, loose or open ground wire. 62. fault and alert messages. From a neighbor's phone. The Sandblaster® line of commercial gas water heaters feature unique Hydro-Cannon™ technology to keep sediment from settling in the tank, thus keeping it extremely energy efficient at all times.

The chart below lists the current readings, the frequency signal displayed by the VFD, and the pressure switch settings needed for the CCB to let the burner operate. This feature increases the hot water available when it is needed the most. SEE THE GAS PRESSURE CHART ON PAGE 4. Turn electrical power off at the source when necessary for service.

Model: SUF-119-400-NEA 300. On a common supply gas line are operating. • Low or no manifold gas pressure to the main burner - see initial. Commercial Technology Selector. Operation of the three lower buttons is defined immediately above them on the screen. Page Loading... State Industries. Whatever model you choose, it will pay off with years of trouble-free service. ACTION: Press Update to accept the change or Cancel to reject it.

Electric Point-of-Use. Factory-Installed Temperature and Pressure Relief Valve. Why Partner With Us.